SPECIAL NOTE
NOTE: Your STOVE WILL NOT FEED FUEL UNTIL the Internal Temperature reaches 120
degrees. This normally takes 10– 15 minutes.
After the Thermal Switch reaches 120 degrees, the Auger will start to feed Fuel at the Rate you
have set the Feed Control. The Circulation Fan will also start (assuming the Fan Control Switch
is turned on) and blow at the speed you have set the Fan Control.
NOTE: If auger is not full of Fuel, it may be necessary to hand feed the fire with a small amount
of fuel until the auger begins to deliver fuel to the burner. Care should be taken when hand
feeding. Open the door slowly and add a small amount of fuel to the burner and continue the
process of hand feeding until you see the fuel drop into burner. This may be necessary on the
first lighting because the Auger is not “primed”. This action will be necessary if the Hopper runs
dry.
IT IS ADVISABLE TO TURN OFF THE POWER SWITCH WHEN YOU
INTEND TO OPEN THE FRONT DOOR. This turns off the Circulation fan
and minimizes ash and smoke escaping. ALWAYS BE
CAREFUL WHEN THE FRONT DOOR IS OPEN
17