JUPITER CM-4400 Control Module Installation and Operating Manual 55
Jupiter Control of Encore
Jupiter Control of Encore
The CM-4400 can send switching commands to a Grass Valley Encore
control system. Encore can then send commands to a router.
The serial ports on the back of the Encore System Controller Board (SCB)
use RJ45 connectors; the
port selected for the CM-4400 connection must be
configured for RS-422 operation with an internal jumper. For more infor-
mation about the SCB ports, refer to the Encor
e installation and user manuals.
Non-Redundant Installation
Figure 17. Connecting to a Non-Redundant Encore Control System
Cabling
A Grass Valley Cat5 cable kit is available in two versions:
• If the SCB is the old style (071 0884 xx series), order kit 174 8216 xx.
•
If the SCB is the new style (071 1000 xx series), order kit 174 8217 xx.
The factory cable must be used with a customer-supplied adapter that must
be wi
red as shown in Figure18. The factory cable is eight inches
long. A
customer-supplied standard Cat5 cable
(and coupler) can be added if
needed. Further instructions are provided with the cable kit.
to routing switcher
Encore SCB
RS−422 port
House time
code
(optional).
See pg.
2−64
CM-4400 System Controller
Serial Port
LAN
071826105_Connecting to a Non-Redundent Encore Control System.