JUPITER CM-4400 Control Module Installation and Operating Manual 57
Jupiter Control of Encore
Figure 20. Customer-Supplied Cable for Connecting CM-4400 to New-style Encore SCB
Software Configuration
The CM-4400 connected to the Encore must be configured using the
Network Description table (page 149) and Serial Protocol table (page 152).
The Serial protocol default setting is: GNP
(Grass Valley Native Protocol),
9600 baud when Jupiter is controlling Encore (Figure21). The Baud rate can
be changed as long as both the Encor
e and CM-4400 configurations match.
Figure 21. Jupiter Controlling Encore - Serial Protocol Table
A router must be defined using the Switcher Description table (page 156).
Including, switcher inputs,
outputs, a CP Level Set, and CP Input/Output
Sets must be defined.
Note If Encore is controlling Jupiter, different software settings are required, see
Encore Control of Jupiter on page 63.
1
6
Rx−
2
7
3
Tx−
8
4
9
5
to CM-4400
Serial port
DB9P
(male)
RJ45P
(male)
Rx+ Receive plus
Rx− Receive minus
Tx+ Transmit plus
Tx− Transmit minus
G Ground
Belden 8723 or equivalent
= Shielded, twisted pair
Rx+
Tx+
G
to Encore SCB
RS−422 port
1
2
3
4
5
6
7
8
Tx−
Rx−
Rx+
Tx+
G
G
G
G
071826105_Customer−Supplied Cable for Connecting CM-4400 to New−style Encore SCB