Video faults continue to occur if Super Slo-Mo inputs lose
and then regain phase alignment while recording is underway.
Description:CR110998
If inputs lose phase alignment, rst restore phase alignment
and then stop and restart the recording.
Workaround:
Multi-Cam and 3D/Video + Key inputs can get out of sync
during record if input 2 is interrupted.
Description:CR111917
First ensure that input 1 and input 2 remain phase locked and
then stop and restart the recording.
Workaround:
Status Pane displays "Embedded audio lost" and "Embedded
audio present" when a record operation begins.
Description:CR112227
These messages do not affect the record operation and can
safely be ignored. If you congure the channel in E-to-E mode,
Workaround:
the messages are not displayed. If viewing messages in
NetCentral, you can lter these messages so they are not
displayed.
Storage Utility
Storage Utility does not open for a nearline SAN. This occurs
when in K2 Cong you select the name of the K2 SAN, which
Description:CR101794
is the top node of the storage system tree, when attempting to
open Storage Utility.
In K2Cong tree view, under the nearline SAN's K2 Media
Server, select the File System Server node to open its property
page. On the property page click Launch Storage Utility.
Workaround:
The Clean Unreferenced Files feature and the Clean
Unreferenced Movies feature are not available in Storage
Utility.
Description:CR108206
Do not attempt to use these features. The features will be
available in a future release.
Workaround:
The Expansion by bandwidth feature is not supported on K2
SANs with RANKs that contain multiple LUNs.
Description:CR109691
Do not attempt to expand by bandwidth on these K2 SANs.
The feature will be available in a future release.
Workaround:
K2 RAID
Firmware le CH_15K6_SAS.N004 has a problem. This is
the disk rmware le for K2 RAID Cheetah 6 15K SAS drives.
Description:CR109174
Do not load CH_15K6_SAS.N004 onto drives. Instead, refer
to compatibility tables in release notes and load the le with
Workaround:
the updated version, which is version N005 at the time of this
writing.
12 May 2010 K2 Version 7.2.7 Release Notes & Upgrade Instructions 103