3. In Storage Utility tree view, expand the node for the K2 RAID, right-click the icon for a RAID
controller, and select Configuration | Network Properties.
The Controller Network Settings dialog box opens.
4. In the Controller Slot Number field enter 0 and then press Enter.
The settings from controller 0 are loaded into the Controller Network Settings dialog box and
are available for you to modify.
5. Enter the control network IP address and other network settings.
6. For SNMP Configuration, enter the IP address of the NetCentral server PC.
You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.
7. For the RAID chassis with two controllers, in the Controller Slot Number field enter 1 and then
press Enter.
The settings from controller 1 are loaded into the Controller Network Settings dialog box and
are available for you to modify.
8. Repeat the previous steps to configure controller 1.
9. Click OK to save settings and close.
10. In Storage Utility click View | Refresh.
Next, bind disk modules.