Power on
Use the Storage Utility to congure the following settings for the K2 RAID controller:
IP address
Subnet mask
Gateway Address
SNMP trap destinations
For K2 RAID, network and SNMP settings are set and stored on the RAID controller module, so
the combined RAID storage devices, including the optional Expansion chassis, exist as a single
entity on the control network.
The RAID storage device is congured by default for the SNMP community name public. If your
sites policies require using a different SNMP community name, contact your Grass Valley
representative.
1. Launch Storage Utility from the K2Cong application.
2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.
3. In Storage Utility tree view, expand the node for the K2 RAID, right-click the icon for a RAID
controller, and select Configuration | Network Properties.
The Controller Network Settings dialog box opens.
4. In the Controller Slot Number eld enter 0 and then press Enter.
The settings from controller 0 are loaded into the Controller Network Settings dialog box and
are available for you to modify.
02 February 2012 K2 SAN Installation and Service Manual 197