9. Click OK to close the Bind dialog box and begin the binding process.
The Progress Report dialog box opens, showing the status of the binding process.
10. Close the Progress Report and repeat these steps for other unbound disks.
If specied by your system design, you can bind some disks as Hot Spares.
When you are done, if you did not bind any extra Hot Spares, you should have the following
results:
The disks in the primary RAID chassis and in optional Expansion chassis should be bound as
RAID 6 RANKs, with twelve disks to a RANK.
11. Click Close in Progress Report window.
12. Restart the K2 Media Server.
NOTE: Make sure start up processes on the K2 Media Server are complete before proceeding.
Next, create a new le system.
Related Topics
Identifying disks on page 321
About full/background bind on page 325
Binding Hot Spare drives on page 327
Creating a new file system - Nearline K2 SAN
Prerequisites for the K2 RAID chassis are as follows:
Fibre Channel cable(s) connected
Ethernet cable(s) connected
Power on
Disks bound
Prerequisites for the optional K2 RAID Expansion chassis are as follows:
Fibre channel cable(s) connected
Power on