3. Congure the settings for the interface as follows:
For control network interfaceSetting...
Control is requiredNetwork
The IP address for this interface on the network. Required.IP Address
The device host name. Required.Interface Name
Not recommended. Sets the interface name to SiteCong default convention,
based on the root Site name and device-type.
Set to Default
Unselected is required. Since not selected, the default behavior occurs, which
is to use the device host name in the hosts le.
...use Interface
Name/Aliases in
Host Files...
Not allowedAliases
Allowed, if applicable to the network. The DNS sufx is added to the
interface name.
DNS Sufx
For FTP/streaming network interfaceSetting...
Streaming is requiredNetwork
The IP address for this interface on the network. Required.IP Address
The device host name with the " _he0" sufx added is required. For example,
if the host name is K2prod01, then K2prod01_he0 is required here.
Interface Name
Not recommended. Sets the interface name to SiteCong default convention,
based on the root Site name and device-type.
Set to Default
Selected is required...use Interface
Name/Aliases in
Host Files...
Not allowedAliases
Allowed, if applicable to the network. The DNS sufx is added to the
interface name.
DNS Sufx
For media (iSCSI) network interfaceSetting...
iSCSI (non-Redundant) is required on K2 Media Server for all interfaces of
type iSCSI on basic K2 SAN.
Network
iSCSI (Primary Redundant) is required on K2 Media Server A for all
interfaces of type iSCSI on redundant K2 SAN
iSCSI (Secondary Redundant) is required on K2 Media Server B for interfaces
of type iSCSI on redundant K2 SAN
The IP address for this interface on the network. Required.IP Address
Disabled, since names are excluded from the hosts le. Disregard.Interface Name
02 February 2012 K2 SAN Installation and Service Manual 95
Planning and implementing a K2 SAN with SiteCong

Table of Contents