October 19, 2008 K2 Storage System Version 3.2.74 Release Notes 53
Known problems
Workaround: Cancel the wizard. Doing so does not effect the operation of the K2 ASI Media
Client.
NetCentral
Description: NetCentral reports a Failover Monitor fault, even though Failover Monitor is
actually running with no problem. Also, there is no report of database
replication currently underway. (CR 62119)
Workaround: Verify that Failover Monitor is still running and database replication is
underway by using the Server Control Panel in the K2 System Configuration
application.
RAID
Description: On a Level 3 RAID Expansion Chassis, the expansion adapter fault LED can
stay on, even though no fault is present. (CR73601)
Workaround: This problem does not occur on all expansion adapters. If it occurs on your
expansion adapter, contact Grass Valley Support to fix the problem.
Description: Loading controller firmware simultaneously on two controllers in different
chassis fails. (CR63092)
Workaround: Load firmware on one chassis at a time. Do not load in parallel. Do not use
Storage Utility for other tasks while firmware is loading.
System
Description: A "...service or driver failed..." message appears when the K2 Media Server
starts up. (CR68251)