16
Environment and Location
Mounting the Kahuna Maverik Control Surfaces into a Desk
Mounting the Kahuna Maverik Control Surfaces into a Desk
How to calculate the Width and Depth of a Control Surface
Control Surface Width - The calculation is:-
Total Width MAV Modules and Blanking Modules in a row + 54mm (2.12 in)
Control Surface Depth - The calculation is:-
Number of Rows x 140 mm (5.15 in)
Example: The diagram below is an example of how to calculate the overall width of a Kahuna
Maverik control surface.
Control Surface Width:- Add up all the Widths of the MAV modules (bottom Row):
160 mm + 160 mm + 200 mm + 160 mm + 100 mm = 780 mm
Then add 54 mm to that total:- 780 mm + 54 mm = 834 mm
(54 mm is the combined width of the End Caps)
Control Surface Depth:- 3x Rows so the Depth = 140 mm x 3 = 420 mm
Calculation in Inches:-
Width:- 6.29 in + 6.29 in + 7.87 in + 6.29 in + 3.93 in = 30.67 in
Then add 2.12 in to that total:- 30.67 in + 2.12 in = 32.79 in
Depth:- 5.15 in x 3 = 15.45 in
Note: Each MAVRow width and depth dimensions are unique to a
customers requirements, please use the information below to calculate the
dimensions of the control surface and the cut-out dimensions. Important:
The cutout has to be a minimum of 110mm (4.3 inches) into the desk to
allow clearance for cables and airflow underneath the MAVRow frame.
Note: Widths of MAV Modules and Blanking Modules can be found in Table
1 and Table 3 of this manual.
27 mm
27 mm
834 mm
780 mm
100 mm
160 mm
160 mm
160 mm
200 mm
140 mm 140 mm
140 mm
Example of a Kahuna Maverik Control Surface

Table of Contents