EasyManua.ls Logo

GRASS VALLEY KAHUNA 9600 - Mainframe Power Supplies; Mainframes; System Components Using Internal Power Supplies

GRASS VALLEY KAHUNA 9600
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
Power Supplies
Mainframe Power Supplies
Mainframe Power Supplies
The information below gives an overview of all the power supplies used in the Kahuna 9600
and Kahuna 6400 mainframes.
Caution
System Components Using Internal Power Supplies
Mainframes
The Kahuna 9600 11RU Mainframe is supplied as standard with two power supplies, the two
power supplies are able to run a fully populated mainframe.
A further two power supplies can be fitted to provide dual redundancy if required.
The Kahuna 6400 6RU Mainframe is supplied as standard with two power supplies. A single
power supply is able to run a fully populated mainframe.
The second power supply is fitted as standard to provide redundancy.
Note: To reduce the risk of electric shock, plug each power supply cord into
separate branch circuits employing separate service grounds.
Note: To ensure full dual redundancy, two of the four power supplies must
be powered from independent power sources.
Note: To ensure redundancy, both power supplies must be powered
from independent power sources.

Table of Contents

Related product manuals