348 KAYENNE — User Manual
Section 3 — System Operation
E-MEM Prefs Assignment
By default R-MEM is not assigned to any E-MEM Enable group button. You
use the E-MEM Prefs menu (accessed via
User Setups/Suite Prefs
/E-MEM Prefs), to make an assignment. Touch the R-MEM data pad, then
select the desired Enable button.
Once this assignment has been made, recalling an E-MEM register on the
Master E-MEM Module will recall that same number R-MEM register.
Learning an E-MEM register on the Master E-MEM Module will also learn
the same R-MEM register.
CAUTION Make sure the R-MEM enable group you choose is only enabled when you
actually need to use it during effect recalls. Confusing source selection button
changes can occur otherwise. Using E-MEM Auto Recall can help control
when groups are enabled.
Learning R-MEMs on the Control Panel
When R-MEM has been assigned to an E-MEM Enable button, learns can
be performed from the Control Panel as well as the R-MEM menu.
Note The Learn operation you will use erases any existing information in all the
enabled levels of the current E-MEM register.
1. On the Master E-MEM Module, select the Enable button to which
R-MEM has been assigned. This enables R-MEM for the current effect
register.
2. Setup the desired R-MEM state.
a. Go to the R-MEM Router Select menu (accessed via Router, Control)
and select the router source to be used with each switcher source.
b. Go to the R-MEM menu (touch the R-MEM category selection button)
and enable the desired switcher sources. Select
Auto Recall if you
want the ability to recall R-MEM settings for only the selected
switcher sources.