Output Assignments
Output Assignments
Any outputs can be assigned as fixed outputs, which includes any M/E, Image Store, or
eDPM outputs. In addition, any Logical input source can be assigned to any output.
About GV K-Frame XP Source Definition Outputs
The GV K-Frame XP supports a maximum configuration of 40 outputs: four boards with
eight outputs (32 outputs) and 2 boards with four outputs (8 outputs).
Outputs Modular Outputs
1-8 81-84
9-16 85-88
17-24
25-32
Default Output Assignments
Default output assignments are one-to-one with the Aux buses, beginning with Aux 1.
Change Output Assignments
The Outputs menu is used to change the system output assignments. The current output
assignments can be viewed in this menu. The scrolling list of data pads along the left side of
the screen shows the currently assigned output for each listed output connector. The right
side of the menu shows the items available for assignment to that output connector.
Different choices appear, depending on the Output Type selected, as shown below.