Maintenance
290
M/E Stripe Mapping
Button Hold Down for Joystick Calibration
Calibration settings are saved with the module. Disconnecting, reconnecting, or moving
the module to a different location on the Control Panel (including a different Stripe) should
not affect the calibration for that module.
M/E Stripe Mapping
The recommended PCU port to Stripe multi-pin cable connection order uses the following
conventions:
• Lowest PCU Port > Top M/E Stripe (under Local Aux Stripe if present)
• Next PCU Port > Next lower M/E Stripes in order
• Highest contiguous PCU Port > Local Aux Stripe
• Stripes in the same Suite should use contiguous PCU ports.
By following these cabling conventions, troubleshooting will be easier because the
connections will be consistent.
It is possible to re-map M/E Stripe to PCU port connections. This can be useful if an essential
M/E Stripe (for example, the one with the Multi-Function Module) fails due to a multi-pin
cable problem. That essential M/E Stripe can be re-assigned to a different PCU port that has
an operational multi-pin cable, restoring Kayenne Control Panel operation.
To remap M/E Stripes, on any Transition Module press the three right-most buttons over the
Lever Arm at the same time to enter M/E Stripe Mapping mode.
Move the Joystick to bottom
right and rotate the Z - Axis to
the right and press NEXT button.