Maintenance
308
VP Frame Processor Board Replacement
VP Frame Processor Board Replacement
When replacing the GV K-Frame XP Video Processor Frame control processor board, verify
that the S2 Boot Mode Dipswitch settings are all in the
UP or Normal position. The
dipswitch is located below the SATA drive on the control processor board.
GV K-Frame XP Control Processor Board - S2 Boot Mode Dipswitch Location
Lifetime of the Internal Battery
Battery life of the GV K-Frame XP Video Processor internal battery is dependent on the
operating time of the switcher.
Battery information:
Capacity:1000 mA/h
GV Part Number:146013800
Type:CR 2477
Video Processor Frame Battery Replacement
1 Turn off all power to the Frame before opening it.
2 Using a grounding strap, open the door to the Video Processor Frame and remove the
Controller Board.
3 Remove the old battery by lifting the clip holding it in place.
CAUTION: If the Dipswitch settings are not in the UP or Normal
position, the system may not boot.