Installation & Service Manual
321
Control Panel Board Boot Display Codes
Digit
3 2 1 0
Digit Zero shows the link and FPGA boot status.
*
1.
Module interface link is working (normal/default).
2. FPGA was loaded over application area (normal/default).
+
1.
Module interface link not working: link should display in 1-3 seconds or there may be a hardware issue.
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary!
1.
Module interface link is working (normal/default).
2. FPGA was loaded over application area (normal/default).
!
1.
Module interface link not working: link should display in 1-3 seconds or there may be a hardware issue.
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary!
Digit 1 shows the lower number of the FPGA firmware version.
Digit 2 shows the middle number of the FPGA firmware version.
Digit 3 shows the upper number of the FPGA firmware version. (X1 always shows “!” to see the difference to the released
versions).
Example Codes: Control Panel Module Boot Display
Digit
0
3
7
*
1.
Module interface link is working (normal/default).
2. FPGA was loaded over application area (normal/default).
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
+
1.
Module interface link is working (normal/default).
2. FPGA was loaded over factory area: application area damaged, reprogramming necessary.
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
1.
Module interface link is not working: link should come up after 1-3 seconds, if not there may be a
hardware problem.
2. FPGA was loaded over application area (normal/default).
3. FPGA firmware version is 037 (DS1281.037).
0
3
7
!
1.
Module interface link is not working: link should come up after 1-3 seconds, if not there may be a
hardware problem.
2. FPGA was loaded over factory area --> application area damaged, reprogramming necessary.
3. FPGA firmware version is 038 (DS1281.038).
!
3
5
*
1.
Module interface link is working (normal/default).
2. FPGA was loaded over factory area because X1 doesn't have a application area (normal/default).
3. FPGA firmware version is X1 and 35 (DS5831.035).
!
3
5
0
1.
Module interface link is not working: link should come up after 1-3 seconds, if not there may be a
hardware problem.
2. FPGA was loaded over factory area because X1 doesn't have a application area (normal/default).
3. FPGA firmware version is X1 and 35 (DS5831.038).