EasyManua.ls Logo

GRASS VALLEY KAYENNE - Learn a Q-MEM Register with a Single Device; Learning a Q-MEM Register with Multiple Devices

GRASS VALLEY KAYENNE
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device Control
Karrera Device Control
248
CS-1
12
345 MISC4
I ØØ:ØØ:ØØ:ØØ OU ØØ:ØØ:ØØ:ØØ
D ØØ:ØØ:ØØ:ØØ TC ØØ:ØØ:ØØ:ØØ
GV/BrightStar
K2-1 K2-2 K2-3 K2-4 CLR
CS-1 CS-2 CS-3 CS-4
TC In Out
IS 1 IS 2 IS-3 IS 4
IS 5 IS 6
ENT
In
Jog
For each device, the following device state data is learned into the cue:
Clip name,
Mark-In point for clip,
Mark-out point (may be empty),
Loop flag,
Gang flag, and
A list of ganged devices.
Recalling a cue register can be used to:
Associate devices with the lettered buttons only, so you can set up your DCM for
manual use,
Recall and cue devices without affecting the current letter button selections, and
Both associate the devices with letter buttons and load, cue, and play them.
Device Select
(Turn to Scroll)
Clip
Select
(Turn
to Scroll)
Device Control Module, Q-MEMs
Learn a Q-MEM Register with a Single Device
To learn a simple cue with one device:
1 Select a device by pressing a control button, A - F.
2 Select a clip on that device using the bottom soft knob and press the
Load button to
load the clip. You can then set the mark-in/mark-out points (
Mark In/Mark Out buttons)
and optionally turn on the
Loop button (tallies blue).
3 Pre
ss the LRN button.
a Optionally, press the
Play button (flashes green) to add a play command (so when
the cue register is recalled, the clip will load and play).
4 Press the desired Cue register number button (use the Page and Bank buttons for the
higher numbered registers). The selected Cue register button high tallies red.
Learning a Q-MEM Register with Multiple Devices
8623267_22

Table of Contents

Other manuals for GRASS VALLEY KAYENNE

Related product manuals