Kayenne/Karrera/GV Korona
User Manual
261
Module will recall that same number R-MEM register. Learning an E-MEM register in the
Master E-MEM Module will also learn the same R-MEM register.
CAUTION: : Make sure the R-MEM enable group you choose is only
enabled when you actually need to use it during effect recalls.
Confusing source selection button changes can occur
otherwise. Using E-MEM Auto Recall can help control when
groups are enabled.
Learn R-MEMs from the Control Panel
When R-MEM has been assigned to an E-MEM Enable button, learns can be performed from
the Control Panel as well as the R-MEM menu.
Note: The Learn operation you will use erases any existing information
in all the enabled levels of the current E-MEM register.
1 On the Master E-MEM Module, select the Enable button to which R-MEM has been
assigned. This enables R-MEM for the current effect register.
2 Setup the desired R-MEM state.
a Go to the R-MEM Router Select menu (accessed via Router, Control) and select the
router source to be used with each switcher source.
b Go to the R-MEM menu (select the R-MEM category selection button) and enable
the desired switcher sources. Select
Auto Recall if you want the ability to recall R-
MEM settings for only the selected switcher sources.
3 Press the LRN button in the Control Panel Master E-MEM Module, then press the Page,
Bank, and Register keypad number of the desired register. This will save the current R-
MEM setting in the menu to the header area of that E-MEM effect register and the first
keyframe of the new effect will be created. The corresponding R-MEM register in the
menu will also be updated.