EasyManua.ls Logo

GRASS VALLEY KAYENNE - Change R-MEM on an Existing E-MEM Register; Loading R-MEM Registers; About Empty R-MEM Keyframes; Camera Control with Ethernet Camera Tally

GRASS VALLEY KAYENNE
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device Control
Camera Operations
262
Change R-MEM on an Existing E-MEM Register
1 On the Master E-MEM Module, recall the E-MEM register you wish to change.
2 On the Master E-MEM Module, select the Enable button to which R-MEM has been
assigned.
3 Setup the desired R-MEM state.
a Go to the R-MEM Router, Control menu (accessed via Router, Control) and select
the router source to be used with each switcher source.
b Go to the R-MEM menu (select the R-MEM category selection button) and enable
the desired switcher sources. Select
Auto Recall if you want the ability to recall
R-MEM settings for only the selected switcher sources.
4 On the Master E-MEM Module, press Learn. The R-MEM setting in the menu will be
updated to the header area of that E-MEM effect register. Keyframes existing in the
effect will remain unchanged. The corresponding R-MEM register in the menu will
also be updated.
Loading R-MEM Registers
Like E-MEM registers, loading an R-MEM register from disk does not affect the current work
buffer. If an effect is loaded in the work buffer and that register number containing different
settings is loaded from disk, the register will need to be recalled before any changes in state
occur.
About Empty R-MEM Keyframes
If the R-MEM enable button is on when keyframes on other levels are inserted into the
effect, R-MEM keyframes containing effectively no data will also be added to the effect and
appear on the Timeline menu. These keyframes are only system artifacts and do not
influence the running of the effect.
Camera Control with Ethernet Camera Tally
GV Switcher Camera Integration provides the ability to place cameras into a usable but not
fully shaded setup/rehearsal mode. The GV Switcher can connect to up to 99 cameras via
the Grass Valley LDK Connect Gateway. Cameras can be acquired by multiple suites.
Note: For configuration information, refer to the
Kayenne/Karrera/GV Korona Installation & Service Manual.
Switcher camera control is provided in the menu.
Camera control from the GV Switcher system makes camera source setup fast and easy by
allowing you to:
Turn color bars on/off to quickly identify which source is associated with a camera,
Control a subset of camera settings:
Auto Iris enable/disable,
Auto Black level (trigger),
ND (Neutral Density) Filter settings, and
Load a Scene File with a single button push or recall a Scene File with an E-MEM.