c Locate the noted source by either scrolling through the Source list (Logical ID
column) or clicking on the Engineering Source ID data pad and entering the Source
Number noted from the Multiviewer Prefs menu.
d Select the Menu column data pad for the source and enter the new name in the
pop-up keyboard, and select Enter.
9 Repeat selecting windows then input sources for additional assignments.
10 Turn off the Identify feature if on as it can obstruct some of the views.
Note: It is not recommended to have the Identify feature on during
normal operations. The default is off and it is not saved as part of the suite
preferences.
About MV Green Relay Tally Calculations for Multiviewer On-Air and Green
On-Air and Green tally calculations are configured and applied the same as Relay tally.
Three common scenarios for MV Green Tally:
Note: Red On-Air tally overrides Green tally for Multiviewer assigned
sources.
• Look Ahead Preview—In a typical configuration, an LAP calculation can be applied to
Multiviewer so any Multiviewer assigned source selected for on-air transition is green
tally on the monitor. In this example, the green tally communicates that the source can
be taken to air with the next transition. Any upstream sources associated with a
Multiviewer assigned source (for example keyers or eDPM channels) will also tally green
on the monitor when selected on the PST bus.
• Aux Bus—An example of On-Air and Green Aux Bus tally would be to identify on-air
sources feeding monitors located behind the talent on a news or sports broadcast.
• On-Air in another suite—Selected in the On Air Tally tab, in Eng Setup, Switcher Tally,
sources on-air in another suite can be tallied green on the monitor with Multiviewer,
allowing the operator to observe when those sources are on-air.
Configure MV Green Relay Tally for Look Ahead Preview
Applying green tally to LAP (Look Ahead Preview) will place green borders around the
Multiviewer windows on a display when sources are on the PST bus, in a typical
configuration, communicating that those sources are in LAP and can transition to on-air
next.
1
Select
Eng Setup,Sw itcherTaly
.
2 Select the MV Taly button in the Tally System pane (upper right).
3 Select one of the four Tally Calc tabs.
4 Select the Calc Name data button and enter a descriptive name for the calculation;
LAP 1 for Look Ahead Preview in Suite 1 as an example.
5 Assign tributaries to the four Look Ahead Previews:
a Select
LAP 1 then Tributary 4,
b Select
LAP2 then Tributary 3, and so on.