335
Masterpiece
User Manual
Then select “Router Connections”. Here the physical router outputs (Including Matrix and
Levels) need to be mapped to the physical Masterpiece inputs. These connections will form the
“Tie Lines”
After each router connection row is set, touch the {Set} button.
Setting Up Names and Tie Lines
Next, go to the ENG Config - Input Setup menu.
In this menu, select the BNCs that where set to connect to the router destinations in the
“Peripherals - Router Connections” menu and use the “Router Tie Line” parameter set the Tie
Lines to “Yes”. Do this for all the inputs that will become Tie Lines from the router.
Make sure at this point to “Overwrite” or “Save” the ENG Config setup.
Note: For inputs that are set as “Tie Lines”, it is recommended that the
“Source Standard” parameter (in the Eng Config - Inputs menu) is set to
“Auto Standard”.
It's recommended that sources which are off standard (and therefore
requires format conversion) do not come via Tie Lines if hot cutting is
required.