OCP 400 Operational Control Panel User’s Guide (v12.0) 21
Chapter 3 - Setup
Menu Selections Function Level Possible values
OCP setup
page 1
Cam Nr Selects camera number S 1..99
SELECT Connects to selected camera S Press button to connect to the
selected camera
Connector Selects which connector to use
for control
S Ethernet, Serial
Serial Select type of serial connection S RS-232, RS-422 (when available)
OCP setup
page 2
IP CONFIG Go to the IP configuration menu
(“IP and Ethernet configuration”
on page 23.)
F
IRIS Go to the Iris menu (“Iris
(joystick) setup” on page 24.)
S
BlackPot Assigns black rotary control
function
BBlack, Flare
CLOCK Go to the clock menu (“Clock”
on page 24.)
F
OCP setup
page 3
LCD BackL Sets LCD display backlight level B 0..99 (50)
LCD Contr Sets LCD display contrast level B 0..99 (50)
Buzzer When switched on, a buzzer
signal sounds when a CALL
signal is received from the
camera.
BOn, Off
Txt Bright Sets brightness of dot matrix
text displays
B 1..20 (20)
OCP setup
page 4
Tally Leds Selects Tally LEDs intensity B Low, Medium, High, Full
Text Leds Sets rotary text-LEDs intensity B 0..99
LED Low Sets button Low-Level
illumination
B0..99
LED High Sets button High-Level
illumination
B0..99
OCP setup
page 5
MB Res Master black rotary resolution F Vfine,fine,normal,coarse,Vcoarse
MB Mode Master black mode F Linear, Mixed
ETH CONFIG Go to the Ethernet configuration
menu (“IP and Ethernet
configuration” on page 23.)
F
Preview On Air status to Preview button F On Air On, On Air Off
OCP setup
page 6
Tally OnOff Defines the tally input on
preview connector.
F Low/High / High/Low / Open/High
/ High/Open
—
—
Lock+Free Defines which part of the panel
stays locked when Free button
is pushed (in Locked mode).
B Upper, Joystick, Matching