42 XCU eXchangeable Control Unit User’s Guide (v1.6)
Chapter 5 - XCU menu reference
5.7 Diagnostics menu
Time Left 0..179 sec User 2 Shows time left after activating a trial
license.
Menu item Values Default Level File Description
Menu item Values Default Level Stored Description
Cable Power
Camera Power On, Off On User 2 (advanced settings)
Connector None, Fiber, Triax,
Error
None User 2 (advanced settings)
Status Unknown, Open,
Power Off,
Overload, Short,
Cam Off, Cam On,
Error
Unkno
wn
User 2 (advanced settings)
Int.Error Unknown, VMtest,
STtest, CStest,
FBtest, Start,
Shutdown,
nonFlex, Family
Unkno
wn
User 2 (advanced settings)
Communication
Cam Connected Yes, No No User 2 (advanced settings)
C2IP Panels 0..99 0 User 2 (advanced settings)
LDK Connect Gw Yes, No No User 2 (advanced settings)
Ethernet
MAC-Address <####> User 2 Cradle (advanced settings)
Link state Connected,
Disconn
Disconn User 2 (advanced settings)
Link type Unknown, 10Mb/
Half, 10Mb/Full,
100Mb/Half,
100Mb/Full,
Negotiate
Unkno
wn
User 2 (advanced settings)
Loopback test
Loopback test Off, On Off Service (advanced settings)
Data count <####> Service (advanced settings)
Data errors 0..65535 0 Service (advanced settings)
Data loss 0..65535 0 Service (advanced settings)
Transmission
Transm. path T2F Conv, F2T
Conv, 3GTriax,
3GFiber, Unknown,
None
None User 0 (advanced settings)
Transm. select
Priority Auto, Triax, Fiber Auto User 0 (advanced settings)