EasyManua.ls Logo

GRAUPNER mz-24 PRO - Stick Adjustments; Stick Tension and Centering Adjustments; Stick Length Adjustment

GRAUPNER mz-24 PRO
240 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Deleting Switches
To delete, press the value field of the switch or
control to be removed. The active window will ap-
pear. Press the CLR button:
Select
CLR
NO
LOGIC
Press
Canceling the Switch Assignment
To cancel an assignment, press the NO button:
Select
CLR
NO
LOGIC
Press
The active menu will disappear.
Control Switch Assignment
Logical controls can be assigned to a function
wherever there is a CTL value field. To assign a
control, press NULL button near or next to any
CTL line or column. An active window will appear.
Turn or move the control that you want to use to
assign. In the example below, left proportional ro-
tary control SL2 was assigned. As soon as the
control is moved, an accessory display will appear:
BACK
CTL
POS
MODE
DIR
SL 2
000
SINGLE
REVERSE
ENT
Continue to move or turn the control. The yel-
low arrow to the right of the bar diagram will move
along the control's throw. Select the position with-
The logical switch display window appears listing
the eight logical switches (L1 - L8) and eight invert-
ed logical switches (L1i - L8i):
L1
L5
L2
L6
L3
L7
L4
L8
BACK
Select logical switch
L1i
L5i
L2i
L6i
L3i
L7i
L4i
L8i
Press the desired button. The logical switch dis-
play closes and returns to the previous menu. The
selected logical switch appears in the CTL value
field. In the example below, L1 appears in the field:
BACK
CH
D/R
EXP
CTL
AILE
+100%
+100%
L1
INC
RES
DEC
PHASE 1
000%
000%
SERVO
SYM
OFF
D/R,EXP
Notice
Do not forget to program the selected logical
switch in the FUNCTION submenu Logical
sw.
Tips
Logical switches can be used to logically intercon-
nect two switches. They can also be used to estab-
lish a control switch as an AND/OR. A total amount
of 8 logical switches L1 - L8 are available, each with
a reversed (inverted) direction L1i - L8i. Refer to the
FUNCTION submenu Logical sw (page 148) for ad-
ditional information.
in the throw and press the ENT button. The pre-
cise position point along the control and produc-
es a value in the POS line. Reverse the switching
direction by pressing the REVERSE button in the
DIR line. Press the button in the MODE line to tog-
gle between SINGLE and DUAL . This chang-
es the function of the control switch from an on/off
switch (like a 2-stage switch) to the switching be-
havior of a 3-stage switch.
Notice
When changing modes, be sure the switching
position is not "000". Otherwise, there is risk
of switching continuously back-and-forth be-
tween the two switching states while the relevant
control is in the middle control position.
Assigning Logical Switch
Logical switches can be assigned to a function
wherever there is a CTL value field. To assign a
control, press NULL button near or next to any
CTL line or column. In the example below, the L1
switch is being assigned through the D/R,EXP dis-
play:
An active window will appear. Press the LOGIC
button:
Select
CLR
NO
LOGIC
Press
BACK
CH
D/R
EXP
CTL
AILE
+100%
+100%
NULL
INC
RES
DEC
PHASE 1
000%
000%
SERVO
SYM
OFF
D/R,EXP
Press
28 Control and switch assignment

Table of Contents

Other manuals for GRAUPNER mz-24 PRO

Related product manuals