English
20
21
Lead batteries
Parameter Short description
Voltage Maximum cell voltage at constant charge (CV)
Current The default value, inherited from the „Proles“ menu to 1C, can be adapt-
ed within the „Maximum capacity“ of the charge port rate and the charger
features, see display 2 of the menu „Settings“ on page 43, in the range of
0.1 to a maximum of 30 A.
Maximal Tempera-
ture
Setting range: 10 ... 80 ° C (Default: 50 ° C). If the temperature sensor is
connected, the charge process is stopped automatically when that tem-
perature is exceeded.
Maximal capacity Setting range: 10 ... 150% in 5% increments, OFF (default value: 120%).
To avoid damage from overcharging, the charge stops when the limit is
exceeded.
Safety timer Setting range: 10 ... 900 minutes in 5 minute increments OFF (default
value:
120 min). To avoid damage from overcharging, the charge stops when
the limit is exceeded.
Once the settings are matching with your wishes, go to ...
Start the charge process
PM 05:39:46
CHARGE
Charge Mode
Discharge Mode
CH1 CH2
00 NiCd Auto Mode
AUTO
NONE
Balancer port is
not connected ...
00:00:00
... Press the ENTER button on the bottom right of the display on the second
display page of the „CHARGE“ menu.
In parallel, the charger checks the balancer port of the active charging channel
CH1 or CH2 and compares the number of cells of the connected battery with
the default settings, whereupon corresponding messages are shown on the
display.
PM 05:39:53
CHARGE
Charge Mode
Discharge Mode
CH1 CH2
AUTO
NONE
00:00:00
Start Delay Time
00 NiCd Auto Mode
5
Then you have about ve seconds - depending on the selected battery type -
to select or adjust other options, see below.