Menu BALANCE
The data concerning your batteries stored in menu “PROFILE” can be added in the menu
“CHARGE” or “DISCHARGE” with the corresponding charge or discharge parameters.
In this menu, you can see the actual parameters as electrical data of your LiFe, LiIo and LiPo bat-
teries and if desired also balance them.
The selected location is displayed at the top of the screen and can be changed by tapping with
your nger or with the supplied pen on the “memory location” eld. Similarly proceed with the other
option elds as shown below.
Parameter Short description
Cell count Cells number of the battery connected to the respective
charger balancer
Battery voltage Actual voltage of the batteries connected to the respective
charge port.
Medium voltage “Battery voltage / cell number” average from cell voltage
Differential volt-
age
Difference between the actually lowest and highest cell
voltage
Max number Number and actual voltage of the cell with the highest cell
voltage
Min number Number and actual voltage of the cell with the lowest cell
voltage
Tapping the DEC button (down arrow) at the bottom of the screen brings to the second page of the
“BALANCE” menu:
PM 01:23:54
CH1 CH2
BALANCE
0.000V
0.0m1 4.124V
0.0m2 4.119V
0.0m3 4.108V
0.0m4 4.114V
0.0m5 0.000V
0.0m6
0.0m7 0.000V
0.000V
0.0m8 0.000V
Cell
Voltage Resistance
In the second screen of the “BALANCE” menu is shown the current voltage of
each individual cell of the battery packs connected to the CH1 or CH2 balanc-
er, maximum of eight cells.
PM 01:23:54
CH1 CH2
BALANCE
0.000V
1 4.124V
2 4.119V
3 4.108V
4 4.114V
0.0m5 0.000V
0.0m6
0.0m7 0.000V
0.000V
0.0m8 0.000V
Cell
Voltage Resistance
13.9m
12.6m
11.6m
10.1m
If the battery has already been charged or discharged or at least if it has been
previously started a display of the internal resistance, for every single cell it will
be shown the internal resistance previously measured in the second page of
the menu “BALANCE”, on the right near the individual cell voltage.
PM 01:23:45
CH1 CH2
BALANCE
Batt cells
Pack Voltage
Avg Voltage
Gap Voltage
Max No.
Min No.
16 LiPo 04s 5500
04
16.466V
4.117V
1
4.124V
3
4.108V
0.016V