7. DATA VIEW SCREEN
7-1. DATA VIEW <1/4>
- This is to display charge status.
INPUT 0.000V -Input Voltage
OUTPUT 0.000V -Output Voltage
TEMPERATURE 0.0`F -Temp of the temp sensor
HIGH TEMP 0.0`F -Max temp of the temp sensor
RESISTANCE 0m
-Battery internal resistance after
operation
CHG TIME 0:00:00 -Charge time after charging
DSCH TIME 0:00:00 -Discharge time after discharging
7-2. CYCLE DATA <2/4>
- This is to store cycle operation and various status.
- Total 11 memories ( Memory 0~10)
- Memory consists of “ROM”, even if power is OFF, the data still leaves.
- Memory “0” is the latest data, and memory 10 is the oldest data.
Data which happens after 10 times should be removed in order.
CYCLE DATA 0<2/4> - Cycle number
END.00/00/00 10:00 - Date and Time for the cycle
CHG CAP 0mAh - Charged capacity
PEAK VOLTS 0.000V - Peak voltage during charging
CHG RESITANCE 0m
- Battery internal resistance at charge
DSCH CAP 0mAh - Discharged capacity
AVG DSCH 0.000V - Average voltage during discharging
DISCHG RES. 0m
- Battery internal resistance at
discharge
- Memory storage
- CHARGE, DISCHARGE MODE
Data is stored to “0” memory
- CYCLE MODE
If D:C->D mode is activated for 10 times, the first discharge is
stored to “10” memory and 1~10 cycles are stored to 9~0
memories.
If CÆD, DÆC mode is activated for 10 times, 1~10 cycles are
stored to 9~0 memories.
The latest data should be stored in Memory “0”.
- STEP CHARGE
Initial discharge Æ “1” memory storage
1
st
~ 4
th
STEP Æ “0” memory storage
- REPEAK CHARGE
Since this mode is to recharge charged battery, the previous
charged data is already stored to “0” memory.