Unscrew the fastening nut of the four-way valve
coil and remove the coil. Wrap the four-way valve
with wet cotton and unsolder the 4 weld spots
connecting the four-way valve to take it out. (Note:
Refrigerant should be discharged firstly.)
Welding process should be as quick as possible
and keep wrapping cotton wet all the time. Be
sure not to burn out the lead-out wire of
compressor.
7. Disassemble Four-way Valve
Operating Procedures / Photos
Respectively unsolder the weld spots of main
capillary and auxiliary capillary to take off the
capillary.
8. Disassemble Capillary
Capillary
9. Disassemble Compressor
Unscrew the three foot-nuts at the foot of the
compressor. Unsolder the suction and the dis-
charge pipes of the compressor,and then care-
fully remove the pipes to take out the compressor.
Four-way Valve
Nut