EasyManua.ls Logo

Gree FLEXX60HP230V1AO - Electrical Parameters and Wiring

Gree FLEXX60HP230V1AO
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GREE DC INVERTER HEAT PUMP CONDENSING UNIT
21
No.
Printing
Interface
No.
Printing
Interface
6
COMM
Communication terminal, same with
COMM1
15
V
Compressor V phase terminal
7
PWR
Drive power supply terminal
16
W
Compressor W phase terminal
8
DC-MOTOR1
DC fan terminal
17
JTAG1
Programming interface (for testing)
9
DC-BUS1
Power discharge terminal (for testing)
-
-
-
Model: GUD60W/A-D
No.
Printing
Interface
No.
Printing
Interface
1
L2-2
PFC induction wire (blue)
8
L1-2
PFC induction wire (white)
2
AC-L
Live wire
9
U
Compressor U phase terminal
3
L1-1
PFC induction wire (brown)
10
V
Compressor V phase terminal
4
N
Neutral wire
11
W
Compressor W phase terminal
5
JTAG1
Programming interface (for testing)
12
PWR
Drive power supply terminal
6
COMM
Communication terminal, same with
COMM
13
DC-BUS
Power discharge terminal (for testing)
7
L2-1
PFC induction wire (yellow)
-
-
-

Other manuals for Gree FLEXX60HP230V1AO