Installation and Maintenance
Service Manual
(1) Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause overheating,
HOHFWULFDOVKRFNRU¿UH
(2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc, from
WKHWHUPLQDOEORFN'RLQJVRPD\FDXVHHOHFWULFVKRFNRU¿UH
Outdoor unit
Indoor unit
Firmly fix the wires with the
terminal screws
Firmly fix the wires with the
terminal screws
When wire length exceeds 10m,
use 2.0mmdiameter wires
123
Terminal block
Electrical
component
box
Wire retainer
Use the specified wire type.
Shape wires so
that the front metal
plate cover will fit
securely.
Firmly secure wire
retainer so that
wires sustain no
external stress.
Front metal
plate cover
Sensor securing plate
CAUTION