Maintenance
Service Manual
Fig.17
Fig.18
B. Disassemble heat discharge pipe
(1) Remove joint B
remove joint B from joint C.(As shown in Fig.17)
(2) Remove joint A: Press the clasp and lift joint A upwards to remove it.(As shown in Fig.18)
joint B+C
upwards
clasp
disassemble
joint A
●Put through the power supply and then press ON/OFF button on remote controller to start the unit.
●Press mode button to select auto, cooling, drying, fan or heating function, and then check if the unit operates normally.
●If ambient temperature is below 16°C, the unit cant operate in cooling mode.
8.4 Operation test