EasyManua.ls Logo

Gree GRS-1.5/TD200ANbA-K - Troubleshooting

Gree GRS-1.5/TD200ANbA-K
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL
55
2 Troubleshooting
2.1 E1 High Pressure Protection
Fault code:
Applicable mode: HOTWATER; SAVE; PRESET; NIGHT
Fault judgment condition and method: E1 is displayed on the wired controller. The troubleshooting
method is shown in the flowchart below.
Possible cause: 1) Poor connection of the water tank temperature sensor; 2) Loose pressure switch
cable; 3) Pressure switch fault; 4) Mainboard fault
Troubleshooting:
E1 high pressure
protection
Check whether the
thermo-bulb of the water
tank is properly installed.
Check whether the
pressure switch is
abnormal.
Check whether the
pressure switch is
properly connected.
Replace the mainboard.
Installed the thermo-bulb
properly.
Re-connect the cable for
the pressure switch.
Replace the pressure
switch.
N
N
N
Y
Y
Y