GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL
71
Attachment: Mapping Table of the Temperature
Sensor Resistance and Temperature
The following tables lists the mapping relationship between resistance of different temperature
sensors and temperature. The resistance for different temperature can be queried during maintenance.
Note: Due to variance in measuring method and temperature sensing, the sensor resistance may
deviate at ±C.
Mapping between the temperature and resistance of 15 kΩ (outdoor ambient temperature sensor)
Temperature (°C )
Resistance (kΩ)
Temperature (°C )
Resistance (kΩ)
-20
144
71
2.523
-19
138.1
72
2.439
-18
128.6
73
2.358
-17
121.6
74
2.28
-16
115
75
2.205
-15
108.7
76
2.133
-14
102.9
77
2.064
-13
97.4
78
1.997
-12
92.22
79
1.933
-11
87.35
80
1.871
-10
82.75
81
1.811
-9
78.43
82
1.754
-8
74.35
83
1.699
-7
70.5
84
1.645
-6
66.88
85
1.594
-5
63.46
86
1.544
-4
60.23
87
1.497
-3
57.18
88
1.451
-2
54.31
89
1.408
-1
51.59
90
1.363
0
49.02
91
1.322
1
46.8
92
1.282
2
44.31
93
1.244
3
42.14
94
1.207
4
40.09
95
1.171
5
38.15
96
1.136
6
36.32
97
1.103
7
34.58
98
1.071
8
32.94
99
1.039
9
31.38
100
1.009
10
29.9
101
0.98

Other manuals for Gree GRS-1.5/TD200ANbA-K