Gree GRS-CP11Pd/NhA-D - Operating Parameters; Operating Range for Temperature and Pressure

Gree GRS-CP11Pd/NhA-D
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heat Pump Pool Heater
9
The above maximum power or maximum current don’t include the power
or current of external engineering water pump.
The noise data is the average sound pressure value measured under
high temperature and mid humidity heating conditions (Dry air 80.6
-Relative humidity 63% - Water inlet temperature 80
) with a distance
of 1m away from the unit.
This parametric is the maximum refrigerant charge amount of the unit.
The recommended maximum pool volume is based on the ideal
heating condition that the pool is well shaded; the filtration system runs
for 15h per day, water temperature is maintained at 80
,and ambient
temperature ≥82.4
.
2.2.2 Operating Range
Use the swimming pool heat pump unit within the following ranges of
temperature and water pressure to ensure safe and efficient operation.
Heating Mode Cooling Mode
Outside temperature
5
~ 113
-15
~ 45
60.8
~ 113
16
~ 45
Water temperature
50
~ 100.4
10
~ 38
50
~ 104
10
~ 40
Setting range from the set point
59
~ 104
15
~ 40
50
~ 104
10
~ 40
Water pressure 0.1 ~ 0.5MPa 0.1 ~ 0.5MPa