EasyManua.ls Logo

Gree GUHD series - Nomenclature

Gree GUHD series
219 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80DWFK6HULHV'&
,QYHUWHU6HUYLFH0DQXDO
4
QSPEVDU
2 NOMENCLATURE
GUHD09NK3C1O
12345678910
NO. Description Options
1 Gree Electric Appliances Inc Capital Letter :G
2 Unit Type U=U-Match Outdoor Unit
3 Product Type
C=Cool Only
H=Heat Pump without Aux Electric Heaters
4
Compressor Power Supply
Type Code
N=Constant Frequency
D=DC Inverter
A=AC Inverter
5 Nominal Cooling Capacity
Nominal Cooling Capacity
=Number×1000Btu/h
6 Climate Type
N=Climate T1 Condition
T= Climate T3 Condition
7 Power Supply Code
K= 220-240V~ 50Hz
M=380-415V 3N~ 50Hz
8 Refrigerant 1 =R22; 2=R407C; 3=R410A
9 Design Code
Design Code: A, B, C, D……
Design Change Code=0 (default)
1,2,3......
10 Unit Code O=Outdoor unit
GFH09TK3C I
12345678 9
NO. Description Options
1 Gree Electric Appliances Inc Capital Letter :G
2 Unit Type F=Duct Type; K=Cassette Type; T= Floor-ceiling Type
3 Product Type
C=Cool Only
H=Heat Pump without Aux Electric Heaters
4 Nominal Cooling Capacity
Nominal Cooling Capacity
=Number×1000Btu/h
5 Climate Type
N=Climate T1 Condition
T= Climate T3 Condition
6 Power Supply Code
K= 220-240V~ 50Hz
M=380-415V 3N~ 50Hz
7 Refrigerant 1 =R22; 2=R407C; 3=R410A
8 Design Code
Design Code: A, B, C, D……
Design Change Code=0 (default)
1,2,3......
9 Unit Code I=indoor unite

Related product manuals