92
Installation and Maintenance
Service Manual
11. Removal Procedure
Step Procedure
7. Remove axial ow fan
Remove the nut on the fan and then remove the axial
ow fan.
8. Remove motor support and motor
Remove the screws xing the motor support and lift the
motor support to remove it.
Remove the screws xing the motor and then remove
the motor.
9. Remove gas valve and liquid valve
Remove the valve support bolck, remove the screws
fixing the gas valve and the liquid valve,unsolder the
welding joint connecting the gas valve and the liquid
valve, remove them.
Note:
Discharge the refrigerant completely befor unsoldering;
when unsoldering, wrap the gas valve with a wet cloth
completely to avoid damage to the valve caused by
high temperature.
Motor support
Motor
Valve Support
Liquid valve
Gas valve