84
4
1
2
3
Removal Procedure
8
Remove the 2 screws fixing 
the gas valve. Unsolder the 
  welding spot connecting gas valve 
     and air return pipe and remove 
     the gas valve. 
 (Note: it is necessary to warp 
     the gas valve when unsoldering 
    the welding spot.)  
Remove the 2 screws fixing 
  liquid valve. Unsolder  the 
  welding spot connecting liquid 
                   valve and remove the liquid valve.
Unsolder  the pipe connected 
with the compressor.
Remove the 3 footing screws
of the compressor and 
remove the 
compressor. 
Remove the 3 footing 
screws of the compressor 
and remove the 
com
p
ressor.
Nut
Compressor 
4-way valve assy 
Unsolder weld point of   
capillary, valve and outlet   
pipe of condensator.   
Then remove the   
capillary. Don’t block the 
capillary when unsoldering it. 
(Note: before unsoldering,   
discharge refrigerants   
completely) 
Remove the compressor