EasyManua.ls Logo

Gree GWC12KF-K3DNA5A

Gree GWC12KF-K3DNA5A
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Y
Y
Y
N
N
N
Y
N
Y
Y
N
N
Y
N
N
Y
Y
N
N
N
Y
Y
Y
(3) Temperature sensor malfunction
Main detection points:
z Is outdoor ambient temperature within the normal range?
z Is indoor and outdoor fan running normally?
z Is the radiating environment inside and outside the unit good enough?
Malfunction diagnosis process:
Troubleshooting
56
Energize the
unit and start it
Voltage between
L and N of
indoor wiring
block
Voltage > 200V?
Check power
supply
Check the
connecting
state of the
connecting
terminal
Reliable
connection
Replace main
board of indoor
unit
Remove the
error?
Adjust
connecting
state
remove the
error?
Replace motor
Finish
Energize the
unit and start
it
Indoor unit
display F1/F2
Indoor unit
display F4/F5
Check connecting
state of outdoor
temperature sensor
Reliable
connected?
Replace
Tesmepnesroarture
Sensor
Remove error?
Replace parts
of outdoor
electric box
Check connecting
state of indoor
temperature
sensor
Adjust
connecting state
Remove error?
reliable
connected?
Replace
temperature
sensor
Remove error?
Replace main
boarudn iotf indoor
Adjust
connecting state
Remove error?
Finish