111
Installation and Maintenance
Service Manual
Valve supprt
Liquid valve
gas valve
Step Procedure
10. Remove gas valve, liquid valve and valve suppprt
Remove the valve support bolck, remove the screws 
fixing the gas valve and the liquid valve,unsolder the 
welding joint connecting the gas valve and the liquid 
valve, remove them.
Note:
Discharge the refrigerant completely befor unsoldering; 
when unsoldering, wrap the gas valve with a wet cloth 
completely to avoid damage to the valve caused by 
high temperature.
Remove the screws  xing valve  support, then  remove 
the valve support.
11. Remove 4-way valve assy
Unsolder the welding joints connecting the 4-way valve 
assy, remove the 4-way valve.
Note:
Before unsoldering the welding joint, wrap the 4-way 
valve with a wet cloth completely to avoid damage to 
the valve caused by high temperature.
12. Remove Capillary Sub-assy
Unsolder the spot weld of Capillary Sub-assy and 
condenser, and then remove the Capillary Sub-assy.
Note:
When unsoldering the spot weld, wrap the Capillary 
Sub-assy with wet cloth completely to avoid damaging 
the valve due to high temperature.
4-way valve assy
Capillary Sub-assy