74
Installation and Maintenance
Service Manual
Indoor tube
temperature s ensor
Main
board
Wi ring
termina l
of motor
Wiring
termina l
of stepping
motor
Screw
G rounding
screw
Wire binder
Cut off the wire binder and pull out the
indoor tube temperature sensor.
Screw off one grounding screw.
Remove the wiring terminals of motor and
stepping motor.
Remove the electric box assy.
Screw off the screws that are locking each
lead wire.
Screw
Wire clip
P ower cord
Rotate the electric box assy. Twist off the screws
that are locking the wire clip and loosen the
power cord. Remove the wiring terminal of
power cord. Lift up the main board and take it off.