)XQFWLRQDQG&RQWURO
wh en sw itching to room temperature display from set temperature or outdoor temperature by the remote controller , room
temperature wi ll be displayed for 5 seconds firstl y and then set temperature display returns.
3.10 Locked protection to PG motor
If the indoor fan motor keep s lo w ro tation speed for a continuous period of time af ter st artup, the unit will stop operation an d
display “H6”.
3. 11 Memory Func tion
Memorized items: mode, up & do wn sw ing, light, set temperature and set fan speed.
When po we r is recovered after po we r failure, the unit wi ll automatically st art operation according to memorized status. After
po we r recovery , the unit wi thout timer setting before po we r failur e wi ll operate according to the last setting; the unit wi th g eneral
timer setting which has not been fulfilled before po we r failure will memorize the timer setting and re-calculate the time afte r .
4 Sp ecial functions (optional)
4.1 HEALTH function
During operation of the indoor unit fan, press HE ALTH button on the remote controller to st art health function (If there is no t
HEAL TH button on the remote controller , the unit defaults health function ON).
4.2 I FEEL function
When I FEEL command is received, the controller wi ll operate according to the ambient temperature sent by the remote
controller (For defrosting and cold blow prevention, the unit operates according to the ambient temperature sensed by the air
conditioner). The remote controller wi
ll regularl y send ambient te mperature dat a to the controller . When the data has not been
received for a long time, the unit wi ll operate according to the temperature sensed by the air conditione r. If I FEEL function is
not selected, the ambient temperature wi ll be that sensed by the air conditioner . I FEEL function is not to be memorized.