8.
2.
4.
Selection of installation location
5.
Requirements for electric connection
3.
5.
4.
Make sure that the installation follows the req-
uirement of installation dimension diagram.
air emitted by the outdoor unit will not affect
Outdoor unit
1.Select a location where the noise and outflow
neighborhood.
2.
The location should be well ventilated and dry,
Safety precaution
in which the outdoor unit won't be exposed dir-
ectly to sunlight or strong wind.
3.
4.
Basic requirement
Installing the unit in the following places may cau-
se malfunction. If it is unavoidable, please consu-
lt the local dealer:
5.
6.
7.
2.
1.
laundry.
2.
3.
Grounding requirement
Select a location which is out of reach for chil-
dren and far away from animals or plants. If it
is unavoidable, please add the fence for safety
purpose.
It’s not allowed to be installed on
the unstable
or motive base structure
(such as truck) or in
the corrosive environ
ment (such as chemical
factory).
The location should be able to withstand the
hen installing the unit.
Must follow the electric safety regulations w-
According to the local safety regulations,use
The yellow-green wire in air conditioner is
grounding wire, which can 't be used for other
purposes.
The grounding resistance should comply with
weight of outdoor unit.
1.
The place with strong hea t sources, vapors,
flammable or explosive gas, or volatile objects
spread in the air.
The place with high-frequency devices (such
as welding machine, medical equipment).
The place near coast area.
The place with oil or fumes in the air.
The place with sulfureted gas.
Other places with special circumstances.
The appliance shall not be installed in the
An all-pole disconnection switch having a co-
ntact separation o f at least 3mm in all poles
should be connected in fixed wiring.
with national wiring regulations.
8.
The temperature of refrigerant circuit will be hi-
6.Do not put through the power before finishing
installation.
7.
If the supply cord is damaged, it must
be repla-
from the copper tube.
9.
The appliance shall be installed in accordance
1.
T
he air conditioner is the first class
electric
7
appliance.It must be properly
grounding with
specialized grounding
device by a professional.
Please make
sure it is always grounded effecti-
vely, otherwise it may cause electric shock.
gh, please keep the interconnection cable away
4.
3.
national electric safety regulations.
The appliance must be positioned so tha t the
p
l
u
g is accessible.
ced by the manufacturer, its
service agent or
similarly qualified
persons in order to avoid a
hazard .
Properly connect the live wire, neutral wire and
grounding wire of power socket.
5.
Be sure to cut off the power supply
before pr-
qualified power supply circuit and air switch.
Make sure the power supply matches with the
requirement of air conditioner.
Unstable power
supply or incorrect wiring or malfunction. Pl-
ease install proper power supply cables before
using the air
conditioner.
oceeding any work related to
electricity and safety.
Air-conditioner
Air switch capacity
07K、09K、12K
10A
18K
GWH24QDXE-K6DNB2Z/O
GWH24QDXE-K6DNC2Z/O
GWH24AGDXE-K6DNA1Z/O
16A
GWH24YEXF-K6DNA1D/O
GWH24YEXF-K6DNA1Z/O
GWH24AVEXF-K6DNA1A/O
GWH24AUDXF-K6DNA1B/O
25A
Air switch capacity
Including an air switch with suitable capacity,
please note the following t able . Air switch sh-
ould be included magnet buckle and heat ing
buckle function, it can prot ect the circuit-s hort
and overload. (Caution: please do
not use t he
fuse only for protect the circuit)