:DUQLQJ
When installing or relocating the unit, be sure to keep the refrigerant
circuit free from air or substances other than the specified refrigerant.
$Q\SUHVHQFHRIDLURURWKHUIRUHLJQVXEVWDQFHLQWKHUHIULJHUDQWFLUFXLWZLOOFDXVH
V\VWHPSUHVVXUHULVHRUFRPSUHVVRUUXSWXUHUHVXOWLQJLQLQMXU\
When installing or moving this unit, do not charge the refrigerant which
is not comply with that on the nameplate or unqualified refrigerant.
2WKHUZLVHLWPD\FDXVHDEQRUPDORSHUDWLRQZURQJDFWLRQPHFKDQLFDO
PDOIXQFWLRQRUHYHQVHULHVVDIHW\DFFLGHQW
When refrigerant needs to be recovered during relocating or repairing the
unit, be sure that the unit is running in cooling mode.Then, fully close the
valve at high pressure side (liquid valve).About 30-40 seconds later, fully
close the valve at low pressure side (gas valve), immediately stop the unit
and disconnect power. Please note that the time for refrigerant recovery
should not exceed 1 minute.
,IUHIULJHUDQWUHFRYHU\WDNHVWRRPXFKWLPHDLUPD\EHVXFNHGLQDQGFDXVH
SUHVVXUHULVHRUFRPSUHVVRUUXSWXUHUHVXOWLQJLQLQMXU\
During refrigerant recovery, make sure that liquid valve and gas valve are
fully closed and power is disconnected before detaching the connection pipe.
,IFRPSUHVVRUVWDUWVUXQQLQJZKHQVWRSYDOYHLVRSHQDQGFRQQHFWLRQSLSHLVQRW
\HWFRQQHFWHGDLUZLOOEHVXFNHGLQDQGFDXVHSUHVVXUHULVHRUFRPSUHVVRU
UXSWXUHUHVXOWLQJLQLQMXU\
When installing the unit, make sure that connection pipe is securely
connected before the compressor starts running.
,IFRPSUHVVRUVWDUWVUXQQLQJZKHQVWRSYDOYHLVRSHQDQGFRQQHFWLRQSLSHLVQRW
\HWFRQQHFWHGDLUZLOOEHVXFNHGLQDQGFDXVHSUHVVXUHULVHRUFRPSUHVVRU
UXSWXUHUHVXOWLQJLQLQMXU\
Prohibit installing the unit at the place where there may be leaked corrosive
gas or flammable gas.
,IWKHUHOHDNHGJDVDURXQGWKHXQLWLWPD\FDXVHH[SORVLRQDQGRWKHUDFFLGHQWV
Do not use extension cords for electrical connections. If the electric wire
is not long enough, please contact a local service center authorized
and ask for a proper electric wire.
3RRUFRQQHFWLRQVPD\OHDGWRHOHFWULFVKRFNRUILUH
Use the specified types of wires for electrical connections between the
indoor and outdoor units. Firmly clamp the wires so that their terminals
receive no external stresses.
(OHFWULFZLUHVZLWKLQVXIILFLHQWFDSDFLW\ZURQJZLUHFRQQHFWLRQVDQGLQVHFXUH
ZLUHWHUPLQDOVPD\FDXVHHOHFWULFVKRFNRUILUH
Safety precautions for installing and relocating the unit