10
Technical Information
Service Manual
5. Electrical Part
5.1 Wiring Diagram
● Indoor Unit
●Instruction
Symbol Symbol Color Symbol Symbol Color Symbol Name
WH White GN Green CAP Jumper cap
YE Yellow BN Brown COMP Compressor
RD Red BU Blue Grounding wire
YEGN Yellow/Green BK Black / /
VT Violet OG Orange / /
Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
600007062603
BK
COM-OUT
BU
BN
M1
RT1
RT2
PE
DC-MOTOR
T-SENSOR
SWING-LR1
E
TEST-COM
AC-L
SWING-LR2
M3
M2
SWING-UD-PUSH
M5
M6
M4
AP2
DISP1
AP3
COM-PC
AP4
CONNECTION BOARD
AP5
M7
J1
DISPLAY
HUMAN
COM-TRANS
COM-MAIN
N(N1)(N2)
L1
MAGNETIC RING
TEMP.
SENSOR
ROOM TUBE
TEMP.
SENSOR
FAN
MOTOR
MOTOR 1
LEFT-RIGHT
MOTOR 2
LEFT-RIGHT
EXTRUSION
MOTOR
SWING
MOTOR
UP-DOWN
AP1:PRINTED CIRCUIT BOARD
CAP
JUMP1
YEGN
YEGN
OUTDOOR UNIT
USED FOR AFTER-SALES DETECTION
APPLICABLE FOR THE MODEL WITH
AFTER-SALES INSPECTION LINE
DISPLAY BOARD
WIFI DETECTION BOARD
EVAPORATOR
HUMAN BODY INDUCTION METER
HUMAN DRIVE MOTOR
SWING SWING
LEFT
EXTRUSION
MOTOR
RIGHT