EasyManua.ls Logo

Gree GWH12QC-K6DNA1D/O - Pipe Expansion and Inspection; Detailed Pipe Expansion Steps; Working Temperature Ranges; Temperature Limits for Various Models

Gree GWH12QC-K6DNA1D/O
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Technical Information
Service Manual
Parameter Unit Value
Model GWH24QE-K6DND2I
Product Code CB461006800
Power
Supply
Rated Voltage V
220-240
Rated Frequency Hz 50
Phases 1
Power Supply Mode Outdoor
Cooling Capacity W 7000
Heating Capacity W 7200
Cooling Power Input W 2000
Heating Power Input W 1845
Cooling Current Input A 9.15
Heating Current Input A 8.44
Rated Input W 3800
Rated Current A 16.42
Air Flow Volume(SH/H/MH/M/ML/L/SL) m
3
/h 1250/1100/1000/950/900/850/750
Dehumidifying Volume L/h 2.4
EER W/W 3.5
COP W/W 3.9
SEER W/W 7
HSPF W/W /
Application Area m
2
27-42
Indoor
Unit
Indoor Unit Model GWH24QE-K6DND2I/I
Indoor Unit Product Code CB461N06800
Fan Type Cross-ow
Fan Diameter Length(DXL) mm Φ108X830
Cooling Speed(SH/H/MH/M/ML/L/
SL)
r/min 1250/1100/1000/950/900/850/800/600
Heating Speed(SH/H/MH/M/ML/L/
SL)
r/min 1400/1250/1100/1050/1000/900/850
Fan Motor Power Output W 50
Fan Motor RLA A 0.35
Fan Motor Capacitor μF /
Evaporator Form Aluminum Fin-copper Tube
Evaporator Pipe Diameter mm Ф7
Evaporator Row-n Gap mm 1.5
Evaporator Coil Length (LXDXW) mm 850X25.4X342.9
Swing Motor Model MP35CJ/MP24HF
Swing Motor Power Output W 2.5/1.5
Fuse Current A 3.15
Sound Pressure Level(SH/H/MH/M/
ML/L/SL)
dB (A) 49/47/44/42/40/38/36
Sound Power Level(SH/H/MH/M/
ML/L/SL)
dB (A) 65/61/58/56/54/52/50
Dimension (WXHXD) mm 1078X325X246
Dimension of Carton Box (LXWXH) mm 1145X410X335
Dimension of Package(LXWXH) mm 1148X413X350
Net Weight kg 16.5
Gross Weight kg 20

Other manuals for Gree GWH12QC-K6DNA1D/O