207
Installation and Maintenance
Service Manual
Remove the 3 foot nuts fixing compressor and then
lift the compressor upwards to remove the
compressor and damping cushion.
Note:
Keep the ports of discharge pipe and suction pipe
from foreign objects.
Remove the screws connecting the support
(condenser) and condenser assy,and then remove
the support(condenser).
Remove the 2 screws fixing the condenser and
chassis, and then lift the condenser upwards to
remove it.
Steps Procedure
10. Remove condenser sub-assy
9. Remove compressor
compressor
support
condenser
chassis subassy
sub-assy
a
b