126
Installation and Maintenance
Service Manual
Step Procedure
Remove screws xing the electric box
subassembly; loosen the wire bundle and
unplug the wiring terminals. Then lift the
electric box to remove it.
Remove the screws xing the isolation
sheet and then remove the isolation
sheet.
a
b
Unsolder the welding joint connecting the
capillary, valves and the outlet pipe of
condenser to remove the capillary. Do not
block the capillary with welding slag
during unsoldering.
Unsolder the welding joint connecting the
capillary, valves and the outlet pipe of
condenser to remove the capillary. Do not
block the capillary with welding slag
during unsoldering.
10.Remove Electric Box Assy
11. Remove isolation sheet
12.Remove compressor
cut-off valve
4-way valve
isolation sheet
Electric Box Assy