Installation and Maintenance
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant
completely before removal.
Location of
step motor
Axile bush
Horizontal louver
Right filter
Front
case
Groove
Left filter
Front panel
Open the front panel. Push the left and
rightlters to make them break away from
thegroove on the front case. Then remove
the leftand right lters one by one.
Push out the axile bush on horizontal louver,
Bend the horizontal louver with hand and
then separate the horizontal louver from the
crank shaft of step motor to remove it.
Separate the panel rotation shaft from
the groove xing the front panel and then
removes the front panel.
Screw off the 2 screws that are locking the
display board.
Note:
Applicable for A1/A3/A5/A6/B2/B4/B6/B8/C2/
C4 panel.
1.Remove fter assy
2.Remove horizontal louver
3.Remove panel and display
Panel
Screws
Screws
Screws
A2/A3/A6 display
A5/B2/B4/B8/C4 display
Front panel
Panel rotation
Groove
A1/A5/B6/C2 display