5
Technical Information
Service Manual
2.4 Cooling and Heating Data Sheet in Rated Frequency
Rated cooling
condition(°C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
frequency
(Hz)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
27/19 35/24 18K 0.9 to 1.1 12 to 14 75 to 37 Super High High 52
Rated heating
condition(°C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
frequency
(Hz)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
20/- 7/6 18K 2.8 to 3.0 70 to 35 2 to 4 Super High High 65
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5m.
Cooling:
Heating:
2.5 Noise Curve
Indoor side noise when blowingOutdoor side noise when blowing
50
52
54
56
58
60
62
64
15 30 45 60 75
Compressor frequency(Hz)
Noise dB(A)
Indoor fan motor rating speed
Noise/dB(A)
20
30
40
50
60
Cooling Heating
SHHMHMMLLSL