106
Installation and Maintenance
Service Manual
Step Procedure
     6.Remove electric box assy
a Remove the screw xing electric box assy.
①
Cut off the wire binder and pull out the
indoor tube temperature sensor.
②
Screw off one grounding screw.
③
Remove the wiring terminals of motor, cold 
plasma generator and stepping motor.
④
Remove the electric box assy.
⑤
Screw off the screws that are locking each.
Rotate the electric box assy. Twist off the screws 
that are locking the wire clip and loosen the power 
cord. Remove the wiring terminal of power cord. 
Lift up the main board and take it off.
Instruction:Some wiring terminal of this products 
is with lock catch and other devices.The pulling 
method is as below:
1.Remove the soft sheath for some terminals at 
rst, hold the circlip and then pull out the terminals,
2.Pull out the holder for some terminals at 
first(holder is not available for some wiring 
terminal).hold the connector and then pull the 
terminal.
b
C
Main board
Wiring terminal
of motor
Wiring terminal 
 of stepping motor
Screws
Screw
Wire clip
Circlip
Holder
Connector
Soft sheath
Power cord
Wire binder
Grounding
 screw
Indoor tube
temperature sensor
Electric box assy
Electric box
Step motor
Screw
Wiring terminal 
of cold plasma
generator